Friday, June 12, 2015

CO/IP CALL TIME RESTRICTION

CO/IP CALL TIME RESTRICTION
Description
The system can be programmed to limit the length of outgoing calls by specified stations. When a specified station places an outgoing call, the system initiates the Call Restrict timer and, 15 seconds prior to expiration, a warning tone is delivered. At expiration, the system terminates the call returning the external CO/IP line to idle.
In PGM 142 – 21 : CO CUT OFF TIMER is added.
By using this timer, CO Base call time restriction is possible.
Operation
System
Operation of this feature is automatic when assigned
Conditions
1. Once activated, the Call Warning Tone timer continues timing while the call is connected to the system even if the call is transferred or picked up at another station.
2. There are two kinds of CUT OFF timer. One is Station base, the other is CO base(It is newly added). If two timers are assigned simultaneously, call can be followed by shorter timer.

No comments: